NOTE
For printing in "Express" mode the UV lamp power level is fixed at the highest possible level by
the printer .
Sound Output
Sound output for the high flow vacuum system is dependent on the following operating
parameters:
• Media type (porous, nonporous)
• Number of vacuum pumps operating
• Level of venting
The following table indicates typical sound outputs from the printer under different operating
conditions:
Media
Porous
(corrugated card-
board)
Non-porous
(flat media)
Non-porous
(warped media)
Open (non-masked) vacuum holes will greatly increase sound output. All exposed vacuum holes
should be masked when vacuum is applied to the table.
Pumps Active
(Recommended)
3
1
3
Printing on the High Flow Vacuum Table
Vents Active
25%-100%
0
0
Chapter 5 - Operating the Vacuum System
Sound Output
(dBA)
73-78
64-68
66-70
101