Blower Capacity
Outlet noise level
Prefilter
Carbon Filter
Top Filter or for
FC model
Unit Body
Warranty
Certification
Note: Specifications subject to change without notice.
Minimum Requirements for an Air Filtration System
Air Filtration SystemMinimum Specifications
Blower Capacity (air flow rate)
Particulate Filtration
(smallest filtered particle)
Total Activated Carbon Filtration (by mass)
Air intake height (maximum, measured from
floor)
NOTE
Emissions from UV inkjet printers are denser than air. Therefore, any air filtration system used in
conjunction with the printer must have air intakes below the height of the print table.
3000 cfm
Under 68db
1" (2.54 cm) Graduated Density Polyester
Activated carbon filter (15lbs refillable)
0.3 micron, high surface area or
24lb Activated Carbon Filter
Galvanized steel, Powder Coated
1 year
CE / UKCA
Chapter 10 - Maintaining the Duster 3000FC Air Filtration System
Metric (SI)
3
85 m
/min
1 µ
32 kg
<90 cm
Duster 3000
Imperial
3
3000 CFM (ft
/min)
0.00004 inches
70 lbs
<36 inches
195