Siemens 6SL3120-2TE21-0AA3 Manual page 435

Booksize power units
Table of Contents

Advertisement

Motor Modules Booksize
6.3 Motor Module with external air cooling
Note
Disturbance of the 2 x 9 A Double Motor Module with 300% overload during operation on a
16 kW Line Module
The maximum output of a 16 kW Line Module is not sufficient for the operation of a 2 x 9 A
Double Motor Module with 300% overload.
• Do NOT operate the 2 x 9 A Double Motor Module with 300% overload on a 16 kW Line
Module.
• Use at least a 36 kW Active Line Module or Smart Line Module for operation with 300%
overload.
• Only operate a 2 x 9 A Double Motor Module on a 16 kW Line Module when the
maximum current is limited to 2 x I