Double Motor Modules (300% Overload) - Siemens 6SL3120-2TE21-0AA3 Manual

Booksize power units
Table of Contents

Advertisement

6.2.8.2

Double Motor Modules (300% overload)

Table 6- 15
Technical data Double Motor Modules Booksize (2 x 3 to 2 x 9 A) with 300% overload
Internal air cooling
Output current
Rated current (l
)
n
Base-load current (I
)
H
Intermittent duty current (I
s6
Peak current (l
)
max
Output voltage
DC-link current I
d max
DC-link voltage
(up to 2000 m above sea level)
DC-link capacitance
Overvoltage trip
Undervoltage trip
1)
Electronics power supply
Electronics current drawn
at 24 VDC
Current carrying capacity
DC-link busbars
Reinforced DC-link busbars
24 VDC busbars
Unit rating
2)
Based on I
(600 VDC; 4 kHz)
n
Based on I
H
Total power loss
(including electronics losses, see Power loss
tables (Page 781))
Max. pulse frequency
without derating
with derating
Max. ambient temperature
without derating
with derating
Sound pressure level
Cooling method
Cooling air requirement
Max. permissible heat sink temperature
Weight
Default for 400 V line systems; undervoltage trip threshold can be reduced by up to 80 V and is adjusted to the
1)
parameterized rated voltage
Rated power of a typical standard induction motor at 400 V 3 AC.
2)
Booksize Power Units
Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
6SL3120-
A
ACrms
A
) 40%
A
ACrms
A
ACrms
V
ACrms
A
DC
V
DC
μF
V
DC
V
DC
V
DC
A
DC
A
DC
A
DC
A
kW
kW
W
kHz
kHz
° C
° C
dB(A)
m
/h
3
° C
kg
6.2 Motor Modules with internal air cooling
2TE13-0AA4
2TE15-0AA4
2 x 3
2 x 5
2 x 2.6
2 x 4.3
2 x 3.5
2 x 6
2 x 9
2 x 15
0 ... 0.717 x DC-link voltage
7,2
12
510 ... 720
220
820 ± 2 %
380 ± 2 %
24 (20,4 ... 28,8)
1,15
100
150
20
2 x 1.6
2 x 2.7
2 x 1.4
2 x 2.3
97,6
132,6
4
16
40
55
< 60
Internal fan
29,6
84
78
5,3
5,3
Motor Modules Booksize
2TE21-0AA4
2 x 9
2 x 7.7
2 x 10
2 x 27
22
2 x 4.8
2 x 4.1
187,6
92
5,5
395

Advertisement