Table 6- 33
X1 motor connection and X11 brake connection for Single Motor Modules 45 A to 200 A
For ring cable lugs without insulation
1)
The circuit for protecting the brake against overvoltage is integrated in the Motor Module and does not need to be
2)
installed externally. The max. load current is 2 A, the min. load current 0.1 A.
WARNING
Danger to life as a result of a hazardous voltage at the 0 V to 48 V DC terminals
Death or serious injury can result when live parts are touched in the event of a fault.
• Only connect protective extra-low voltages (PELV / SELV) to all connections and
terminals between 0 to 48 V DC.
Booksize Power Units
Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Terminal
U2
V2
W2
PE connection
+ (BR+)
- (BR-)
6.4 Motor Modules with cold plate
Technical data
45 ... 60 A:
Threaded bolts M6 / 6 Nm
1)
85 A:
Threaded bolts M8 / 13 Nm
1)
132 ... 200 A:
Threaded bolts M8 / 13 Nm
1)
45 ... 60 A:
Threaded bolts for motor cables: M6 / 6 Nm
Threaded hole for PE: M6 / 6 Nm
85 A:
Threaded bolts for motor cables: M8 / 13 Nm
Threaded hole for PE: M6 / 6 Nm
132 ... 200 A:
Threaded bolts for motor cables: M8 / 13 Nm
Threaded hole for PE: M8 / 13 Nm
X11 brake connector
:
2)
Voltage: 24 V DC
Max. load current: 2 A
Minimum load current: 0.1 A
Type: Spring-loaded terminal 2 (Page 754)
Max. cross-section that can be connected 2.5 mm
The brake connector is part of the prefabricated cable.
Motor Modules Booksize
1)
1)
1)
1)
1)
1)
:
2
443