Input Power Requirements
rp24xx server input power requirements are listed as follows:
Stand Alone Server Power Requirements
•
Nominal Rated Voltage: 100 or 240 VAC
•
Input Voltage:
80 to 135 VAC
176 to 269 VAC
•
Input Frequency: 47 to 66 Hz
•
Input Current: 1.0 amps at maximum load with input voltage of 88 VAC and 47 Hz
If an Uninterruptible Power Supply (UPS) is to be used, ensure that it is properly connected to the server.
Power cord plugs for stand-alone servers are available to meet unique power configurations used all over the
world.
Cabinet Mounted Server Power Requirements
Cabinet-mounted servers have the same power requirements as stand-alone servers. However, the power
cords for cabinets are dependent on the type of Power Distribution Unit (PDU).
PDU power cords with one end stripped are also available for attaching country-specific power plugs. Refer to
cabinet documentation for further cabinet-specific electrical power information.
Chapter
Input Power Requirements
63