Configuring Pfc (Pcm8024-K Only) - Dell PowerEdge M420 Configuration Manual

Dell powerconnect m8024-k user's configuration guide
Hide thumbs Also See for PowerEdge M420:
Table of Contents

Advertisement

console(config)#interface gi1/0/4
console(config-if-Gi1/0/4)#switchport protected 0
console(config-if-Gi1/0/4)#exit
console(config)#interface gi1/0/9
console(config-if-Gi1/0/9)#switchport protected 0
console(config-if-Gi1/0/9)#exit
console(config)#exit
5 Verify the configuration.
console#show storm-control gi1/0/1
Bcast
Intf
Mode
------ ------- ------- ------- ------- ------- -------
Gi1/0/1 Enable
console#show service-acl interface gi1/0/1
Protocol
---------------
CDP
VTP
DTP
UDLD
PAGP
SSTP
ALL
console#show switchport protected 0
Name......................................... "clients"
Member Ports: Gi1/0/1, Gi1/0/2, Gi1/0/3, Gi1/0/4, Gi1/0/9

Configuring PFC (PCM8024-k Only)

The network in this example handles both data and voice traffic. Because the
voice traffic is time sensitive, it requires a higher priority than standard data
traffic. The voice traffic uses VLAN 100 and has an 802.1p priority of 5, which
is mapped to hardware queue 4. IP phones are connected to ports 3, 5, and 10,
Bcast
Mcast
Level
Mode
10
Enable
Mode
----------
Disabled
Enabled
Disabled
Disabled
Enabled
Disabled
Disabled
Configuring Port-Based Traffic Control
Mcast
Ucast
Level
Mode
5
Disable
Ucast
Level
5
711