HP D5970A - NetServer - LCII Installation And Configuration Manual page 128

Netraid series
Hide thumbs Also See for D5970A - NetServer - LCII:
Table of Contents

Advertisement

Chapter 11
Suggested solution:
1. Press any key to enter HP NetRAID Express Tools.
2. Run the View/Add Configuration option of HP NetRAID Express Tools,
as described in the HP NetRAID Series User Guide in Information
Assistant.
3. Use View/Add Configuration to examine both configurations, the one on
the drives and the one in NVRAM.
4. Resolve the configuration mismatch by selecting one of the two
configurations to use.
Configuration of NVRAM and drives mismatch for Host Adapter - x
Run View/Add Configuration option of Configuration Utility.
Press any key to enter the Configuration Utility.
Problem: There is more than one adapter, and the configuration stored in the
NVRAM of adapter x does not match the configuration stored in the drives.
Suggested solution:
1. Press any key to enter HP NetRAID Express Tools.
2. Run the View/Add Configuration option of HP NetRAID Express Tools,
as described in the HP NetRAID Series User Guide in Information
Assistant.
3. Use View/Add Configuration to examine both configurations, the one on
the drives and the one in NVRAM.
4. Resolve the configuration mismatch by selecting one of those
configurations to use.
1 Logical Drive Failed
Problem: One logical drive failed to sign on.
Suggested solution:
1. Verify that all physical drives are connected and powered on.
2. Use a utility, such as HP NetRAID Assistant or HP NetRAID Config, to
determine which physical drives are not responding and thereby make the
logical drive unavailable.
3. Correct the problem with the physical drive by reconnecting, replacing, or
rebuilding it.
120
Troubleshooting