Power Supply Module Indicators - HP D5970A - NetServer - LCII Installation Manual

Hp netserver lxr 8000 installation guide
Hide thumbs Also See for D5970A - NetServer - LCII:
Table of Contents

Advertisement

Chapter 2

Power Supply Module Indicators

Each of the HP NetServer power supply modules has the indicators in Figure 2-6:
PWR
PRFL
FAIL
Table 2-3. Power Supply Module LED Descriptions
Control
PWR
Lights solid green when system is powered up. If the system
(Power)
is not powered up but is connected to AC power (so that
standby voltage is available), the LED blinks green. If there
is no AC power, the LED is dark.
PRFL
Blinks yellow if the speed of the power supply's internal fan
(Predictive Fail)
falls below acceptable levels. Power supply has not failed, but
may do so soon.
FAIL
Lights solid yellow when power supply fails. Blinks yellow
(Power Supply
when power supply is drawing more current than it should,
Failure)
because of a short-circuit in the power supply or elsewhere in
the server. If the short-circuit is in the power supply, the
power supply shuts down. If the short-circuit is in the server,
the server shuts down.
Figure 2-6. Power Supply LEDs
Description
Controls, Indicators, and Ports
11

Advertisement

Table of Contents
loading

Table of Contents