Date Of Manufacture (Page 0E, Code 0001); Accounting Date (Page 0E, Code 0002) - Fujitsu MAX3073NC - SCSI,80, Dell DC961,Hard Drive Scsi Logical Interface Specifications

Specifications
Hide thumbs Also See for MAX3073NC - SCSI,80, Dell DC961,Hard Drive:
Table of Contents

Advertisement

Parameter Data Formats

4.2.8.1 Date of manufacture (Page 0E, Code 0001)

Bit
Byte
4
5
6
7
8
9
10
11
12
13
The year and week in the year that the device was manufactured shall be set in the parameter field
defined by parameter code 0001h. The date of manufacture shall not be savable by the application client
using the LOG SELECT command. The date is expressed in numeric ASCII characters (30h-39h) in the
form YYYYWW, as shown above.

4.2.8.2 Accounting date (Page 0E, Code 0002)

Bit
Byte
4
5
6
7
8
9
10
11
12
13
4-64
7
6
5
(MSB)
X'0001' (Parameter code)
(Date of Manufacture)
DU
DS
TSD
0
1
0
X'06' (Parameter Length)
(MSB)
Year of manufacture (4 ASCII characters)
(MSB)
Week of manufacture (2 ASCII characters)
7
6
5
(MSB)
X'0002' (Parameter code)
(Accounting Date)
DU
DS
TSD
0
0
0
X'06' (Parameter Length)
(MSB)
Accounting date Year (4 ASCII characters)
(MSB)
Accounting date week (2 ASCII characters)
4
3
2
ETC
TMC
0
0
0
4
3
2
ETC
TMC
0
0
0
1
0
(LSB)
LBIN
LP
0
1
(LSB)
(LSB)
1
0
(LSB)
LBIN
LP
0
1
(LSB)
(LSB)
C141-C010

Advertisement

Table of Contents
loading

This manual is also suitable for:

Maw3073Maw3147Maw3300Max3036Max3073Max3147 nc series

Table of Contents