refrigeration
42" Built-In Refrigerators
Installation Specifications
Product Weight – 600 Lbs.
Voltage Rating – 120V / 60 Hz / 15 or 20 Amps
Connected Load (kW Rating) @ 120 Volts = 0.65 kW
(For use on adequately wired 120V, dedicated circuit
having 2-wire service with a separate ground wire.
Appliance must be grounded for safe operation.)
Amps @ 120 Volts = 5.4 Amps
Always consult local and national electric & plumbing
codes.
Cutout must be prepared with electrical and water supply
located as shown. When possible, recess copper water
line and electrical outlet.
Water line can enter opening through floor or rear wall.
Copper tubing recommended between cold water line and
water connection location. Water line tubing recommended
is 48" minimum length by 1/4" diameter. Installation of
easily accessible shutoff valve in water line required.
Notes:
A 4" min. door clearance is required when
using 90ϒ door stop position. Drawer access
is maintained, but removal is restricted.
To determine door swing interaction with
adjacent cabinets and countertops refer to
Product Installation Guide on web at
electroluxicon.com .
Optimum door swing factory set for 130°. When installing
next to wall where handle may make contact, allow 4"
minimum clearance for 90° door swing. At 90° door stop
position, drawer access will be maintained but removal
will be restricted.
Refrigerator must be placed on level surface of hard
material, same height as flooring. Surface must support
approximately 1500 Lbs. when fully loaded. Unit
equipped with 4-point leveling.
Refrigerator door handles (PN # 241650502) are designed
to accommodate both framed and custom panels.
(Handles ship in separate box.)
Custom Panel Specifications
For 1/4" framed or 1/4" custom panel construction and
installation details, refer to Custom Panel Installation above.
For 3/4" custom panel construction and installation details,
and to determine door swing interaction with adjacent
cabinets and countertops, refer to Product Installation
Guide on the web at electroluxicon.com.