E30Mc75Jps E30Mc75Jss - Electrolux ICON appliances Design Manual

Table of Contents

Advertisement

Microwave Combination Ovens
30"
/
"
7
8
46
/
"
5
8
Allow at least
23
/
" clearance
1
4
for door depth
when open
Installation Specifications
Product Weight – 240 Lbs.
Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208
Volt, 60 Hertz AC only electrical supply with ground
required on separate circuit fused on both sides of line.
Connected Load (kW Rating) @ 240 / 208 Volts =
7.1 / 6.1 kW
Amps @ 240 / 208 Volts = 30 / 30 Amps
Recommended Circuit Breaker – 40 Amps
Always consult local and national electric codes.
Minimum 23-1/4" clearance for oven door depth
when open.
2
/
"
1
2
min.
28
1
/
"
4
45
/
"
1
4
45
/
"
3
Power
8
min.
supply
location
46"
(left
max.
bottom
rear)
Spacer
11
/
"
1
2
suggested
distance
24
/
"
5
8
4
/
"
1
2
min.
required
30" min.
24" min.*
28
/
"min.
1
2
(critical
29" max.
dimension)
Bottom cutout
edge must be
finish cut
2" min.
Suggested distance from floor is 11-1/2". Minimum
required distance is 4-1/2".
Minimum 24" deep cutout dimension is critical for proper
installation, to ensure that oven's faceplate will fit flush
against cabinet front.
Full oven base of solid plywood or similar material
required, capable of supporting 300 Lbs.
Base must be level and cabinet front must be square.
Microwave Combination Oven is NOT approved to be
used in stackable or side-by-side installation.
e l e c t ro l u x i c o n . c o m
planning
information
For models:
E30MC75JPS
E30MC75JSS
4" x 4"
opening
to route
armored
Note:
For planning
cable
purposes only. Refer
to Product Installation
Guide on the web at
Full base
electroluxicon.com for
required
detailed instructions.
to support
Specifications subject
300 lbs.
to change.
3" max.
Electrical
junction
box location
Installation drawing shown