Electrolux ICON appliances Design Manual page 16

Table of Contents

Advertisement

30" Gas Range
E30GF74HPS
planning
information
For 30" model:
E30GF74HPS
Note:
For planning
purposes only. Refer
to Product Installation
Guide on the web at
electroluxicon.com for
detailed instructions.
Specifications subject
to change.
Optional
Accessories
Stainless Steel
Island Trim Kit
(for use in place
of backsplash)
PN # 903132-9010
4" Stainless
Steel Kick Plate
PN # 318352601
Black Knobs Kit
PN # 903108-9010
16
cooking
Full-Gas Freestanding Ranges
Installation Specifications
Product Weight – 259 Lbs.
Voltage Rating – 120V / 60 Hz / 15 or 20 Amp
Connected Load (kW Rating) @ 120 Volts = 0.6 kW
(For use on adequately wired 120V, dedicated circuit
having 2-wire service with a separate ground wire.
Appliance must be grounded for safe operation.)
Amps @ 120 Volts = 7 Amps
Always consult local and national electric and
gas codes.
Range ships with 3/4" factory regulator.
LP Gas conversion kit supplied.
Overhead cabinetry should not exceed a 13"
maximum depth.
Allow 34" minimum clearance between top of rangetop
and bottom of unprotected wood or metal overhead
cabinetry.
Absolute minimum horizontal distance between overhead
cabinets installed to either side of appliance must be no
less than maximum width of appliance.
Allow 5" minimum clearance from edge of rangetop to
nearest combustible wall on either side of unit.
Allow 24" minimum clearance when bottom of wood or
metal overhead cabinet is protected by not less than
1/8" flame-retardant millboard covered with not less than
No. 28 MGS sheet steel, 0.015" stainless steel, 0.024"
aluminum or 0.020" copper.
To reduce risk of fire when using overhead cabinetry,
install vent hood that projects horizontally a recommended
minimum of 5" beyond bottom of cabinets.