E30MO65GSS

Built-In Convection Microwave
Exhaust Duct
Assembly
Faceplate
/
"
7
8
21
/
"
23
32
30"
Allow at least
19" clearance for door
depth when open
Bottom Duct Assembly
19
Installation Specifications
Product Weight – 60 Lbs.
Voltage Rating – 120V / 60 Hz / 15 Amps
Connected Load (kW Rating) @ 120 Volts = 1.55 kW
(For use on adequately wired 120V, dedicated circuit
having 2-wire service with a separate ground wire.
Appliance must be grounded for safe operation.)
Amps @ 120 Volts = 13 Amps
Always consult local and national electric codes.
Allow 19" minimum clearance for 90° door swing.
Built-In installation requires use of 30" Trim Kit
(E30MO65TMK) which is supplied and includes Stainless
Steel Faceplate, Exhaust Duct Assembly and Bottom
Duct Assembly – shipped in separate box.
Minimum 20-1/8" deep oven cutout dimension is critical
for proper installation for oven and faceplate to fit flush
against cabinet front.
Full base of solid plywood or similar material required,
capable of supporting 100 Lbs.
*Note: When used in combination with
another Electrolux ICON
built-in product, a
®
minimum clearance of 3
/
" required from
1
8
bottom of Built-In Microwave cutout to top
edge of companion product's faceplate,
leaving a 2" visible gap between both
product faceplates
24
/
"
5
8
19
/
"
5
8
Power
cord
location
(right
bottom
rear)
20
/
"
29
32
Bottom Duct Assembly
120V/60Hz
grounded outlet
11
5"
/
"
7
8
26
/
"
20
1
1
2
2"
min.
19
/
"
7
8
min.
26
/
"min.
1
20
/
"
2
3
8
27" max.
max.
20
/
"
1
2"
8
min.
(visible
gap)*
/
"
1
2
Outlet should
NOT be located
within shaded
area
/
" min.
8
Base must be level and front of cabinet square for proper
operation.
Grounded outlet should NOT be located in shaded area,
as indicated.
Combination Installations
For installation details refer to Project Planning Section.
Microwave can NOT be installed above any gas wall oven.
Microwave can be built in alone or is approved to be used
in combination with any Electrolux ICON
Wall Oven and / or Warmer Drawer. (Refer to model-
specific Combination Installation Specifications pages.)
When used in combination with another Electrolux ICON
built-in product, a minimum clearance of 3-1/8" required
from bottom of Built-In Microwave cutout to top edge
of companion product's faceplate, leaving a 2" visible gap
between both product faceplates.
e l e c t ro l u x i c o n . c o m
planning
30"min.
information
For model:
E30MO65GSS
Note:
purposes only. Refer
to Product Installation
Guide on the web at
electroluxicon.com for
detailed instructions.
Specifications subject
to change.
Full plywood
base required
to support
100 lbs.
®
Electric Single
®
For planning
69