Electrolux ICON appliances Design Manual page 156

Table of Contents

Advertisement

planning
information
For models:
Built-In
Microwave
E30MO75HPS
E30MO75HSS
Single Wall Oven
E30EW75GPS
E30EW75GSS
Warmer Drawer
E30WD75GPS
E30WD75GSS
E30WD75GTT
Note:
For planning
purposes only. Refer
to Product Installation
Guide on the web at
electroluxicon.com for
detailed instructions.
Specifications subject
to change.
156
project planning
30" Combination Installation
For Built-In Microwave / Single Wall Oven / Warmer Drawer
For detailed product dimensions
and installation specifications, refer
to model-specific product page and
installation guide on web
30" Built-In
Microwave Cutout
21" min.
21
/
"max.
1
For models:
2
E30MO75HPS
2"
E30MO75HSS
(visible
gap)*
30" Electric Single
Wall Oven Cutout
28
1
/
" min.
2
For models:
28
/
"max.
7
8
E30EW75GPS
E30EW75GSS
1
/
" min.
3
4
30" Warmer
Drawer Cutout
9
/
" min.
7
8
10
/
" max.
1
For models:
4
E30WD75GPS
E30WD75GSS
4
/
" min.
1
2
E30WD75GTT
required
Full plywood base
required to support
100 lbs.
Installation Specifications
30" Combination Installation Specifications
Always consult local and national electric codes. (Refer
to product-specific electrical specifications on this page.)
Minimum 24" deep cutout dimension is critical for proper
combination install ation, to ensure that each built-in
product's faceplate will fit flush against cabinet front.
Bases must be level and cabinet front must be square.
Minimum 4-1/2" required distance from bottom of
Warmer Drawer cutout to floor.
Respect critical dimensions as noted for proper
installation of built-In products.
Minimum 23-1/4" clearance needed for Wall Oven
door depth when open.
30" Built-In Convection Microwave Specifications
Product Weight –
(E30MO75HPS / E30MO75HSS) 84 Lbs.
Voltage Rating – 120V / 60 Hz / 15 Amps
Connected Load (kW Rating) @ 120 Volts = 1.6 kW
(For use on adequately wired 120V, dedicated circuit
having 2-wire service with a separate ground wire.
Appliance must be grounded for safe operation.)
Amps @ 120 Volts = 13.7 Amps
Full oven base of solid plywood or similar material
required, capable of supporting 150 Lbs.
Minimum 2-1/8" clearance required from bottom of Built-In
Microwave cutout to top edge of Wall Oven's faceplate,
leaving a 2" visible gap between both product faceplates.
30" Electric Single Wall Oven Specifications
24"min.
30
/
" min.
1
8
6"
4"
18"
28
/
" min.
1
2
28
3
/
" max.
4
C L
24"min.**
28
/
" min.
1
(critical
2
28
/
" max.
3
dimension)
4
28
/
"min.
1
2
28
/
" max.
3
4
4"x 4" opening to route
armored cable
Product Weights –
(E30EW75GPS) 178 Lbs. / (E30EW75GSS) 175 Lbs.
Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208
Volt, 60 Hertz AC only electrical supply with ground
required on separate circuit fused on both sides of line.
Connected Load (kW Rating) @ 240 / 208 Volts =
4.0 / 3.0 kW
Amps @ 240 / 208 Volts = 16.6 / 14.4 Amps
To support Wall Oven, two 3"-wide x 3/4" thick planks
must be installed as a base, capable of supporting
200 Lbs. Do NOT use full base, since planks are
necessary to allow for proper air displacement.
30" Warmer Drawer Specifications
Product Weights – (E30WD75GPS /
E30WD75GSS) 49 Lbs. / (E30WD75GTT) 41 Lbs.
Voltage Rating – 120V / 450W / 60 Hz / 15 Amps
Connected Load (kW Rating) @ 120 Volts = 0.45 kW
(For use on adequately wired 120V, dedicated circuit
having 2-wire service with a separate ground wire.
Appliance must be grounded for safe operation.)
Amps @ 120V = 3.75 Amps
Full base of solid plywood or similar material required,
capable of supporting 100 Lbs.
120V/60Hz
grounded electrical
outlet should NOT
be located within
shaded area
* Minimum 2
clearance required
Full plywood base
from bottom of
required to support
Built-In Microwave
150 lbs.
cutout to top edge of
Wall Oven's faceplate,
leaving a 2" visible
Two 3" wide
gap between both
by
3
/
" thick
4
product faceplates.
planks must be
installed, capable
** Critical dimension –
of supporting
MUST be applied
200 lbs.
Maximum height
Bottom of
depends on critical
oven cutout
dimension (11
††
Electrical junction
box for Wall Oven
11
/
"min.**
5
must be lower than
8
(critical
the Warmer Drawer
dimension)
cutout
Electrical junction
box location
/
"
1
8
/
")
5
8

Hide quick links: