Electrolux ICON appliances Design Manual page 89

Table of Contents

Advertisement

Island Vent Hoods
S H
A
K
P
Counter Height
36" standard
C
PRE-INSTALLATION CALCULATIONS
K = Kitchen height
A = Canopy height
C = Counter height
H = Hood height for
installation
P = Preferred height
of hood bottom
H = K-C-P
above counter
S = Chimney
(recommended
structure height
30"- 36")
for installation
S = H-A
Installation Specifications
Product Weight – 90 Lbs.
Island / Peninsula Ceiling-Mount Installation
Sones Rating – 11.5
Voltage Rating – 120V / 60 Hz / 15 Amps
Connected Load (kW Rating) @ 120 Volts = 0.72 kW
(For use on adequately wired 120V, dedicated circuit
having 2-wire service with a separate ground wire.
Appliance must be grounded for safe operation.)
Amps @ 120 Volts = 6.26 Amps
Always consult local and national electric codes.
Check local building codes for installation requirements,
as they may vary per locale.
To prepare mounting surface, installation of supports
required above ceiling drywall.
Vent unit outside of building only.
Exhaust Duct Required – 8" round
Air outlet - 7
12
/
"
9
/
"
3
7
4
16
39
/
"
3
8
For most efficient airflow exhaust, use a straight run or as
few elbows as possible.
Use metallic flex ducting only to connect rigid duct directly
to transitions (if allowed by code).
Thermal breaks such as short section of nonmetallic duct,
should be used in areas of extreme cold.
Cold weather installations should have additional backdraft
damper installed.
For most efficient operation, position hood low to cooktop.
Recommended installation is 30" - 36" above countertop.
Pre-Installation Calculations
Select hood preference height (P) that is comfortable for
user (30"-36" recommended, 24"-36" allowed).
Calculate hood height (H) for installation (H = K-C-P).
Confirm that (H) is within minimum to maximum range for
hood. If not, adjust installation.
Calculate chimney structure height (S). Use formulas,
check dimensions of hood. Save calculation for use later
in installation.
/
" diam.
7
8
Wiring box
Top
Dimensions
from base of
hood to ceiling,
and include
clearance
required for
installation.
27
/
"
9
16
e l e c t ro l u x i c o n . c o m
planning
information
For 40" model:
E40PV100FS
Controls
Note:
5"min.
20
/
"max.
purposes only. Refer
1
2
to Product Installation
Guide on the web at
electroluxicon.com for
detailed instructions.
Specifications subject
16
/
"
9
to change.
16
33"
min.
41
/
"
9
16
max.
11"
2"
Optional
Accessories
32-11/16" Flue
Extension
PN # EXPV100S
For planning
89