Island Vent Hoods
S H
A
K
P
Counter Height
36" standard
C
PRE-INSTALLATION CALCULATIONS
K = Kitchen height
A = Canopy height
C = Counter height
H = Hood height for
installation
P = Preferred height
of hood bottom
H = K-C-P
above counter
S = Chimney
(recommended
structure height
30"- 36")
for installation
S = H-A
Installation Specifications
•
Product Weight – 90 Lbs.
•
Island / Peninsula Ceiling-Mount Installation
•
Sones Rating – 11.5
•
Voltage Rating – 120V / 60 Hz / 15 Amps
•
Connected Load (kW Rating) @ 120 Volts = 0.72 kW
(For use on adequately wired 120V, dedicated circuit
having 2-wire service with a separate ground wire.
Appliance must be grounded for safe operation.)
•
Amps @ 120 Volts = 6.26 Amps
•
Always consult local and national electric codes.
Check local building codes for installation requirements,
as they may vary per locale.
•
To prepare mounting surface, installation of supports
required above ceiling drywall.
•
Vent unit outside of building only.
•
Exhaust Duct Required – 8" round
Air outlet - 7
12
/
"
9
/
"
3
7
4
16
39
/
"
3
8
•
For most efficient airflow exhaust, use a straight run or as
few elbows as possible.
•
Use metallic flex ducting only to connect rigid duct directly
to transitions (if allowed by code).
•
Thermal breaks such as short section of nonmetallic duct,
should be used in areas of extreme cold.
•
Cold weather installations should have additional backdraft
damper installed.
•
For most efficient operation, position hood low to cooktop.
Recommended installation is 30" - 36" above countertop.
Pre-Installation Calculations
•
Select hood preference height (P) that is comfortable for
user (30"-36" recommended, 24"-36" allowed).
•
Calculate hood height (H) for installation (H = K-C-P).
•
Confirm that (H) is within minimum to maximum range for
hood. If not, adjust installation.
•
Calculate chimney structure height (S). Use formulas,
check dimensions of hood. Save calculation for use later
in installation.
/
" diam.
7
8
Wiring box
Top
Dimensions
from base of
hood to ceiling,
and include
clearance
required for
installation.
27
/
"
9
16
e l e c t ro l u x i c o n . c o m
planning
information
For 40" model:
E40PV100FS
Controls
Note:
5"min.
20
/
"max.
purposes only. Refer
1
2
to Product Installation
Guide on the web at
electroluxicon.com for
detailed instructions.
Specifications subject
16
/
"
9
to change.
16
33"
min.
41
/
"
9
16
max.
11"
2"
Optional
Accessories
32-11/16" Flue
Extension
PN # EXPV100S
For planning