planning
information
For models:
E30WD75GPS
E30WD75GSS
Note:
For planning
purposes only. Refer
to Product Installation
Guide on the web at
electroluxicon.com for
detailed instructions.
Specifications subject
to change.
Installation drawing shown
with professional series model.
Optional
Accessories
ServeWare
PN # 5304447729
56
cooking
Warmer Drawers
Stand-Alone Installation
23
/
"
3
26"
8
30"
Overall depth with
drawer fully extended
(includes handle) – 44
1
/
"
8
Warmer Drawer /
Single Wall Oven
Combination Installation
Installation Specifications
Product Weight – 49 Lbs.
Voltage Rating – 120V / 450W / 60 Hz / 15 Amps
Connected Load (kW Rating) @ 120 Volts = 0.45 kW
(For use on adequately wired 120V, dedicated circuit
having 2-wire service with a separate ground wire.
Appliance must be grounded for safe operation.)
Amps @ 120V = 3.75 Amps
Full plywood base required, capable of supporting
100 Lbs.
Base must be level and cabinet front must be square.
9
7
/
" min.
8
10
/
" max.
1
4
4
/
" min.
1
2
required
distance
to floor
/
"
7
Power cord
8
location (right
center rear)
11
/
"
1
4
28
/
"
1
2
28
/
" min.
1
2
min.
28
/
" max.
3
4
28
7
/
"
8
max.
30" min.
9
/
" min.
7
8
10
/
"max.
1
4
Two 3" wide
x
/
" thick
3
4
planks must be
installed, capable
of supporting
200 lbs.
Warmer Drawer / Wall Oven
Combination Specifications
To support Wall Oven when using in combination with
Warmer Drawer, two 3"-wide x 3/4" thick planks must
be installed as a base, capable of supporting 200 Lbs.
Do NOT use full base, since planks are necessary
to allow for proper air displacement.
Combination Installations
Warmer Drawer can be used alone, or is approved to
be used in combination with any Electrolux ICON
Oven. (Refer to Combination Installation Specifications
and drawing on this page.)
Warmer Drawer is approved to be used in combination
with any Electrolux ICON
Microwave and / or Electric Single Wall Oven. (Refer to
model-specific Combination Installation Specifications
pages in Project Planning Section.)
28
/
" min.
23
/
" min.
1
5
2
8
28
/
" max.
24" max.
3
4
Full plywood
base required to
support 100 lbs.
4" x 4" opening
to route armored cable
24" *
Bottom
(critical
of oven
dimension)
cutout
11
/
"
5
8
min.*
Electrical
junction box
location
®
High-Speed Oven / Built-In
®