JVC VN-H37U Instructions Manual page 45

Hd network camera
Hide thumbs Also See for VN-H37U:
Table of Contents

Advertisement

H
Alarm (continued)
Trigger1, Interval,
Trigger2
Position Number
Day/Night (VN-H37U and
VN-H237VPU only)
Time
Pre-Trigger
Post-Trigger
Sunday to Saturday
For the VN-H137U/H237U
Trigger 1 : Sets a condition to record an alarm.
[Set values: Position, Motion Detection, Tampering Detection, time]
Interval: Unavailable.
Trigger 2 : Unavailable.
For the VN-H37U/H237VPU
Trigger 1 : Sets a condition to record an alarm.
[Set values:Position, Motion Detection, Tampering Detection,
Day/Night, time]
Interval: Unavailable.
Trigger 2 : Unavailable.
For the VN-H57U/H257U/H257VPU/H157WPU
Trigger 1 : Sets a condition to record an alarm.
[Set values: Pin Input1 Make, Pin Input1 Break, Pin Input2
Make, Pin Input2 Break, Position, Audio Detection1,
Audio Detection2, Motion Detection, Tampering
Detection, Day/Night, Time]
Interval: [Set values: 1 to 3600]
Trigger 2 : [Set values: Pin Input 1 Make, Pin Input 1 Break,
Position Number is displayed if Trigger1 is set to APositionB.
This function executes an action if the trigger is moved to the
position entered.
[Set values: 0 to 19]
Day/Night is displayed if Trigger1 is set to ADay/NightB.
Color
: Executes an action when the image changes from Black
and White to color.
Black and White: Executes an action when the image changes
from color to Black and White.
[Set values: Color, Black and White]
Memo:
● This function is valid only for models with Day and Night.
Time is displayed if Trigger1 is set to ATimeB.
This function executes an action at the time you have entered.
[Set values: 00H00M-24H00M]
Sets a trigger time before FTP recording (a recording time before
alarm input) in seconds.
[Set values: 0 to 5 to 60] sec
Sets a trigger time after FTP recording (a recording time after
alarm input) in seconds.
[Set values: 0 to 5 to 60] sec
Sets the start and end time of recording for each day of week.
[Set values: Unmask All, Mask All, Unmask Span, Mask Span]
If you have selected ASpecify the time period for invoking the actionB
or ASpecify to stop the actionB, you must set the time period.
[Set values: 00H00M-24H00M]
* The [Set values] in bold letters are factory defaults.
Pin Input 2 Make, Pin Input 2 Break]
45