Continued from the previous page (when WINDOW has been set to "NORMAL")
1REGISTER NO.
0(0~3)
2MEAS SHAPE
RECTANGLE CIRCLE ELLIPSE
3MEAS AREA
MOVE UP.L(224,20) LO.R(287,271)
4MASK NO.
0(0~3)
5MASK SHAPE
NO RECTANGLE CIRCLE ELLIPSE
6MASK AREA
MOVE UP.L(224,208) LO.R287,271)
7AUTO REGIST
EXEC(L LIMIT ONLY U&L LIMITS)
8TERESHOLD
U.LM255 L.LM100(0~255)
9INVERT B/W
NO YES
0BINARY PROCESS
FIXED THRESHOLD-ADJ(VAR-DIFF VAR-RATE)
qBINARY NOISE FILT
NO EXPD.
wNUM.OF FILT PASS
EXPD.0 CONTR.0(0~5)
eBOUNDARY PROCESS
VALID INVALID
rAREA FILTER
U.LM245760 L.LM00000(0~245760)
tNUM. OF DTECT
X00 Y00(0~64)
OPS-MENU RETURN LOCK EVALUATION
- Each time the ESC key is pressed, the menu screen will change to display all items or to
display individual items, one at a time.
- The data in item 3 varies according to the selection in item 2.
Selection in item 2 Data displayed in item 3
RECTANGLE
CIRCLE
ELLIPSE
- The data in item 6 varies according to the selection in item 5.
Selection in item 5 Data displayed in item 6
NO
RECTANGLE
CIRCLE
ELLIPSE
Ë Mask area
The general area to be measured may contain an object that does not need to be measured. To
eliminate such an object from the measurements, a mask area is used.
Object to be measured
Ë Area filter
This function is used to eliminate objects if their measured area is outside of the upper and lower
limits.
Select "EVALUATION" (or select "EVALUATION" on the [MEAS COND] menu) and press the SET key.
To page 7-5
CONTR. CONTR.
EXPD.
MOVE UP.L (224,208) LO.R (287,271)
CENTER (256,240) RAD. (032)
CENTER (256,240) RAD. (032,032)
No data displayed
MOVE UP.L (224,208) LO.R (287,271)
CENTER (256,240) RAD. (032)
CENTER (256,240) RAD. (032,032)
7-3
BGA/CSP Inspection
(Reference pages)
- Pages 3-4 to 3-6
- Page 3-8
- Page 3-9
- Page 3-11
- Page 3-8
Measurement area
Mask area
7