Sharp IV-S30 User Manual page 209

Compact image sensor camera function and operation
Table of Contents

Advertisement

Setting the Input/Output Conditions
Time chart (when auto mode (level) is selected for as the CCD sampling start)
CCD trigger
cycle
Type selection
input
IV-S33M: X1 to X6
or X1 to X5
CCD trigger
window
(not highlighted)
READY output
(While measuring
or setting = L)
PC calculation
condition
Parallel output
(Y0 to Y7)
17
Specified object type number
Black
White
Trigger
Trigger
Measurement result
is valid at the end of
a measurement
P
P
P
P
Halt PC operation
C
C
C
C
during measurement
When the object type is
changed, all Y output and
auxiliary relays turn OFF.
Restarts CCD sampling automatically after
measurement is completed.
Black
Trigger
P
P
P
P
Halt PC operation
C
during measurement
C
C
C
Parallel output is valid for PC control after
the measurement result is determined.
Result output
Result output
17-14
White
Black
P
P
P
P
P
Halt PC operation
C
during measurement
C
C
C
C
Result output
P
C