Measurement Start Input = Parallel, Object Type Change = Parallel, Result Output = General Purpose Serial/Parallel - Sharp IV-S30 User Manual

Compact image sensor camera function and operation
Table of Contents

Advertisement

(3) Measurement start input = parallel, object type change = parallel, result output = general
purpose serial/parallel
Setting order
[SYSTEM COND]
1I/O CONDITIONS (TO NEXT SUB-MENU)
2COMM.SET
(TO NEXT SUB-MENU)
[I/O CONDITIONS]
1MEAS INP I/F
PARALLEL+SERIAL CCD-TRIG
2SERIAL OUTPUT NO PC-LINK SERIAL
- The data in a block No., set in item "5SET SERIAL BLOCK" on the [OBJECT TYPE I/O] menu,
will be output from the IV-S30 to the personal computer. (See page 17-21.)
Time chart
10 ms
or more
Measurement
start input
(X0)
10 ms
or more
Type selection
input
*
IV-S33M:
X1 to X6
Specified object type number
READY output
(While measuring or setting = L)
Terminate
measurement
(C119)
P
P
P
P
PC calculation
C
C
C
C
condition
When the object type is
changed, all Y output and
auxiliary relays turn OFF.
Parallel output
(Y0 to Y7)
Serial output
Note - Result output: The data to be sent to the personal computer will be response of
general-purpose serial command (code 11
10 ms
or more
Measurement result is valid at the end
of a measurement
Halt PC operation during
P
C
measurement
Result
output
17-7
Setting the Input/Output Conditions
Configuration example
Camera 1 (image capturing)
Camera 2 (image capturing)
Personal computer
Data
Controller
Power supply (24 VDC)
Type selection switch
- See page 17-4
Specified object type number
READY signal is turned ON at the
a
conclusion of the result output.
P
P
P
P
P
P
P
Halt PC operation during
C
C
C
C
C
C
C
measurement
Parallel output is valid for
PC control after the
measurement result is
determined.
Result output
a
).
(H)
Monitor
External trigger X0
(photo sensor or
proximity sensor)
P
P
P
P
P
C
C
C
C
C
17
Result output
Result
output

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iv-s31mIv-s32mIv-s33m

Table of Contents