(5) Measurement start input = CCD trigger, start sampling = parallel, object type change =
parallel, result output = parallel
Setting order 1
[SYSTEM COND]
1I/O CONDITIONS (TO NEXT SUB-MENU)
2COMM.SET
(TO NEXT SUB-MENU)
[I/O CONDITIONS]
1MEAS INP I/F
PARALLEL+SERIAL CCD-TRIG
2START CCD SAMPLE AUTO(EDGE LEVL) PARALLEL SERIAL+USB
3SERIAL OUTPUT NO PC-LINK SERIAL
Setting "17-3 CCD trigger"
Note 1: When the settings listed in section "17-3 CCD trigger" have not been made, a
Note 2: Start sampling input (X0)
Time chart
Measurement
start input
(X0)
Start accd sampling by turning ON
measurement start input (X0).
CCD trigger
cycle
Type selection
input
*
IV-S33M:
X1 to X6
CCD trigger
Black
window
(not highlighted)
READY output
(While measuring or setting = L)
P
P
P
P
P
PC calculation
C
C
C
C
C
condition
When the object type is changed,
all Y output and auxiliary relays
turn OFF.
Parallel output
(Y0 to Y7)
2 (
3)
"CCD TRIG NOT SET. (error 34)" will occur.
1. Sampling will be performed while this terminal is ON. When it is turned OFF, the
sampling will stop.
During sampling, O will flash in the upper right corner of the MAIN OPS MENU.
2. After the measurement is terminated, the sampling will be restarted when the
X0 terminal is changed from OFF to ON.
Specified object type number
White
Trigger
Measurement result
is valid at the end
of a measurement
P
P
P
P
P
P
Halt PC operation
C
C
C
C
C
C
during measurement
Setting the Input/Output Conditions
Configuration example
Camera 1 (image capturing + CCD trigger)
Camera 2 (image capturing)
Remote keypad
Controller
Power supply
(24 VDC)
Warning lamp
External output
(Y0 to Y7)
Black
Trigger
P
P
P
P
P
P
Halt PC operation
C
C
C
C
C
C
during measurement
Parallel output is valid for PC
control after the measurement
result is determined.
Result output
17-9
Monitor
Start sampling input
X0
(photo sensor or
proximity sensor)
Type selection switch
-See page 17-4.
Halt CCD
sampling by
turning OFF
measurement
start input
(X0).
P
P
P
P
P
P
P
P
P
P
P
C
C
C
C
C
C
C
C
C
C
C
Result output