Chapter 12: Multiple Positional Measurements - Sharp IV-S30 User Manual

Compact image sensor camera function and operation
Table of Contents

Advertisement

Chapter 12: Multiple positional measurements

The IV-S30 can detect up to 128 workpieces whose images exceed the specified matching
level (gray search) or threshold value (edge detection) from the reference image.
- The positional deviation measurement needs to have a number of positions registered for
Purpose
measurement. However, this measurement only requires you to register one position and
reduces the set up time.
Measure the position of workpieces with a complicated light level that cannot be converted
Applica-
into binary images.
tion
Gray search
Reference image
[Measured results]
- Number of images detected
- Coordinates and degree of match detected for each image
Edge detection
Example
This is useful for obtaining the distance between the coordinates of a position.
- L1 to L3 can be calculated by measuring distances and angles.
[Measured results]
- Number of images detected
- Coordinates detected
12-1
Multiple position measurement
Four workpieces
detected