17-7 Setting the data output

When you communicate with the IV-S30 using a computer link or a serial communication interface
(general purpose serial IF) in the following conditions, perform steps (1) and (2) below to enable serial
output.
- Computer link: When outputting any data - Pages 19-3 and 19-4
- Communication interface (general purpose serial IF): When executing a measurement run command 4
(processing code 14

(1) Select "ANY" for the serial output

Select "ANY" in the "4SERIAL OUTPUT" item on the [OBJECT TYPE I/O] menu.
Ë Ë Ë Ë Ë Setting procedure
On the [TYPE MEAS COND] menu, move the cursor to item "I/O" and press the SET key.
[TYPE MEAS COND]
1OBJECT TYPE NO.00(0~63) NO YES
OPS-MENU SAVE LOCK TITLE FINAL-CALC FINAL-OUTPUT I/O SYSTEM
[OBJECT TYPE I/O]
1TRIG CCD START NO YES(BIN AVG-GRAYS GRAY-SRC)
2CCD TRIG COND (TO NEXT SUB-MENU)
3SHUTTER SPEED 1/00060(1/30~1/10000)
4SERIAL OUTPUT ANY BLOCK-ASSIGN
1
5SET SERIAL BLOCK BLOCK00 MEAS0 CAM1
OPS-MENU RETURN LOCK

(2) Select "YES" or "NO" for output data

Select "YES" or "NO" on the following menu screens that are displayed as "locked" screens to output
serial data. See the next page for instructions about how to lock the screen.
- The [EVALUATION COND] menu for individual
measurement program
[EVALUATION COND]
1CONDITION SET
2X COORD(MDL0)
3 COORD(MDL0) MENU YES
4
(MDL0) MENU YES
5
(MDL0) MENU YES
6
7ANGULAR DEVIATE MENU YES
8X COORD(MD1)
9 COORD(MDL1) MENU YES
0
(MDL1) MENU YES
q
(MDL1) MENU YES
w
OPS-MENU SAVE RETURN
(When measuring positional deviation)
- The [DISTANCE&ANGLE COND] menu
[DIST&ANGLE COND]
1OBJECT
2DISTANCE NO.
3COND.1
4COND.2
5COND.3
6DISTANCE EVALUAT MENU YES
7RUN A TEST
8NUM-CALC
9OUT-COND
OPS-MENU SAVE RETURN
(To measure an object's "distance" on the distance and angle condition menu)
) - Pages 18-8 and 18-10
(H)
[MENU]
[SERIALOUTPUT]
MENU YES
MENU YES
NO
NO
NO
NO
MENU YES
NO
NO
MENU YES
NO
NO
NO
NO
MENU YES
NO
MENU
[SERIAL OUTPUT]
MENU YES
MENU YES
MENU YES
MENU YES
MENU YES
NO
MENU YES
MENU YES
MENU YES
17-23
Setting the Input/Output Conditions
2
- The "NUMERIC CALC COND" or "FINAL CALC
COND" menu for individual measurement program
[NUMERIC CALC]
[MENU]
1CALC RESULT MENU YES
2TYPE
MENU YES
3FORMULA
MENU YES
4FUNCTION
MENU YES
5UPR&LOW LIMIT MENU YES
6OUTPUT
MENU YES
7RUN A TEST
MENU YES
OPS-MENU SAVE RETURN
(When the numerical calculation condition
menu is displayed)
- When the serial output setting is "NO," no data
(block 0) will be output (the space will be filled
by the next item).
1. Move the cursor to
item "4 SERIAL
OUTPUT" with the up
and down keys, and
press the SET key.
2. Move the cursor to
"ANY" using left and
right keys and press
the SET key.
[SERIALOUTPUT]
NO
17