Isolating The Faulty Part On The Power Supply Board; Isolating The Faulty Part According To The Phenomenon - Epson Stylus PHOTO 890 Service Manual

Color ink jet printer
Hide thumbs Also See for Stylus PHOTO 890:
Table of Contents

Advertisement

EPSON Stylus Photo 890/1280/1290

3.1.2 Isolating the Faulty Part on the Power Supply Board

This section explains how to troubleshoot the following problems:
n
The printer is turned on but it does not perform initialization and no LED
indicators come on.
n
Problems occurs after the printer is turned on.
Be sure to troubleshoot in the order specified since the steps are listed in the
disassembly order to facilitate the job.
NOTE: If you answer "Yes" to a question listed under "Checkpoint", take the action
described to the right under "Action". If "No", proceed to the next step.
Table 3-10. Isolating the Faulty Part on the Power Supply Board
Step
Checkpoint
Action
1
Is the Panel FFC
The power switch for this printer is in the secondary
disconnected from the
side. Therefore, if the FFC does not transmit signals, the
connector on the panel
power supply board is not active despite the main board
board?
operates properly.
2
Is the Panel FFC
The power switch for this printer is in the secondary
disconnected from CN11
side. Therefore, if the FFC does not transmit signals, the
(black, 12-pin) on the
power supply board is not active despite the main board
Main Board?
operates properly.
3
Has the Pin 3 of the panel
Check for the Pin 3 using a circuit tester.
FFC broken?
4
Has the fuse (F1) on the
Check if the F1 located beside CN1 on the power supply
power supply board
board has blown out.
blown out?
5
Is CN1 on the power
Check if CN1 is properly connected. CN1 supplies AC
supply board
power to the primary side of the power supply board.
disconnected?
6
Is CN10 on the main
Check if CN10 on the main board is properly connected.
board disconnected?
CN10 supplies DC voltage to the control circuit.
7
-
Replace the Power Supply Board with a new one.
TROUBLESHOOTING
3.1.3 Isolating the Faulty Part according to the
Phenomenon
Refer to this section if you could not solve the problem in Section 3.1.1.1 or Section
3.1.2 or need more information to isolate the cause according to the exhibited
phenomenon. This section mostly covers the problems relating to the main control
circuit and other parts.
Table 3-11. Phenomenons Exhibited
No.
Phenomenon Exhibited
1
CR motor does not rotate.
2
PF motor does not rotate.
3
Pump/ASF motor does not rotate.
4
Cleaning does not solve the print problem.
Overview
Revision C
Table to refer to
Table 3-12
Table 3-13
Table 3-14
Table 3-15
72

Advertisement

Table of Contents
loading

This manual is also suitable for:

Stylus photo 1280Stylus photo 1290

Table of Contents