Setting the Input/Output Conditions
OUT I/F(PARAL.)
Select a signal output interface, in order to output the measured results externally. The choices
are: "NO," "PC-LINK" or "SERIAL."
NO
PC-LINK Connect to the parallel input on a programmable controller.
SERIAL Connect to a standard serial port.
MANL TYPE CHNG
The object type can be changed manually using the remote keypad on the operation screen.
NO
YES
PARALLEL INP X5
Select the type of input terminal (INPUT) X5.
EXT-INP
REG REF
COMPARE-IMGS
AREA EVAL CORECT
16
No connection. (No output.)
Means that you cannot change the object type manually on the operation screen.
Means that you will be allowed to change the object type manually on the operation
screen. Move the cursor to the "CHG-TYPE" item on the operation screen, and select the
object type No., displayed on the upper part of the screen, using the up and down keys.
- See page 1-10.
External input: The PC function uses the terminal as an external input
signal. -See Chapter 15.
When X5 is turned from OFF to ON, and gray search is selected, the
reference image will be registered in the SDRAM. When edge
detection is selected, the reference coordinates will also be registered.
- To store the reference image in flash memory
Select the SAVE key on any sub menu or use a general purpose
serial command.
- Available measurement programs (gray scale search) Positional
deviation measurement, the degree of match
inspection, multiple positions measurement, multiple degree of match
inspections for register No. 0, model 0
- Applicable measurement program (edge detection) Positional
deviation measurement
- If a reference image has not been specified, an "UNABLE
REGISTER REF.IMG" (X5 reference image register error (code3E))
will occur.
On the operation screen, when parallel input X5 is turned ON, the
controller will transfer a previously registered reference image into its
flash memory for use in performing calculations that compare images.
Total area evaluation correction
- When X5 is ON, the upper and lower limits for the total area
evaluation conditions will be corrected automatically.
- Measurement programs: Area measurement, object counting, and
object identification by binary conversion
16-2