Monitor Output - Sharp IV-S30J User Manual

Compact image sensor camera
Table of Contents

Advertisement

Setting the Operating and System Conditions

[1] Monitor output

When two cameras have been connected to IV-S30J,
you can switch back and forth between the image from
the cameras on one monitor. Also, the monitor screen
2
can be divided into two parts to display the two images
simultaneously.
- Purpose of the setting
To set the conditions in which an image captured
during measurement will be displayed on the
operation screen.
- Output monitor switching
There are two methods for changing the monitor
output: change the TYPE RUN COND settings, use
external input signals through the parallel port to
make changes from outside.
(1) Change the monitor output by changing the TYPE RUN COND settings
Select the "
from the popup menu.
1MONITOR OUTPUT
CAM1
CAM2
CAM1&2
Display examples on the operation screen
- Camera 1 on the whole screen
(When "CAM1" has been specified in item
1MONITOR OUTPUT.)
- Simultaneous display on a divided screen
(When "CAM1&2" has been specified in item
"1MONITOR OUTPUT.")
MONITOR OUTPUT" item on the "TYPE RUN COND" screen and then select an item
Display the camera 1 image on the whole screen.
Display the camera 2 image on the whole screen.
Display the camera 1 image on upper half, and the camera 2 image
on lower half.
F C1 H
SERIAL NO.
8F053G26
MODEL
IV - S33MX
F C1/C2 H
SERIAL NO.
8F053G26
MODEL
IV - S30J
TYPE RUN COND SCREEN SAVE
1MONITOR OUTPUT
CAM1
2CAPTURE IMG
PARTIAL-IMG
3MESSAGE DISPLAY
YES(NUMERIC)
4PATTERN DISPLAY
YES
5SHOW BINARY IMG
YES
6SHOW
FIX IMG
YES
7OPS MAIN DISP
YES
8DISP CHG-EVAL
NO
9PC-MNTR
NO
0THROUGH DISPLAY
NO
qEXTENSION FUNC.
NO
SET=SELECT A MENU ESC=BACK SEL=CHNG IMG TRG=FUNC
Description
- Camera 2 on the whole screen.
(When "CAM2" has been specified in item
1MONITOR OUTPUT.)
2-2
F C1 BRT
CAM1
CAM2
CAM1&2
F C2 H