Siemens SINAMICS G150 Operating Manual page 192

Converter cabinet units 75 kw to 800 kw
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

Diagnosis / Faults and Alarms
F35832
TM DRIVE-CLiQ: Telegram failure
Reaction:
OFF2
Cause:
There is a DRIVE-CLiQ communication error between the control unit and the affected
terminal module.
Remedy:
- Check for break in DRIVE-CLiQ or faulty contacts in connector.
- Check 24 V supply of affected component.
- Replace affected component.
See also: p9916
Acknowl.:
Immediate
F35833
TM DRIVE-CLiQ: fault in cyclic data transfer
Reaction:
OFF2
Cause:
There is a DRIVE-CLiQ communication error between the control unit and the affected
terminal module.
Remedy:
- Check firmware states of affected components.
- Replace affected component.
Acknowl.:
Immediate
F35834
TM DRIVE-CLiQ: Hardware defect
Reaction:
OFF2
Cause:
There is a DRIVE-CLiQ communication error between the control unit and the affected
terminal module.
Remedy:
Replace affected component.
Acknowl.:
Immediate
F35835
TM DRIVE-CLiQ: fault in cyclic data transfer
F35836
Reaction:
OFF2
Cause:
There is a DRIVE-CLiQ communication error between the control unit and the affected
terminal module.
Remedy:
- Check firmware states of affected components.
- Replace affected component.
Acknowl.:
Immediate
F35837
TM DRIVE-CLiQ: Hardware defect
F35838
Reaction:
OFF2
Cause:
There is a DRIVE-CLiQ communication error between the control unit and the affected
terminal module.
Remedy:
Replace affected component.
Acknowl.:
Immediate
F35860 -
CU DRIVE-CLiQ: Data transfer faulted / Telegram faulted
F35871
Reaction:
OFF2
Cause:
DRIVE-CLiQ communication between control unit and at least one other component is
defective.
Fault value
Bit 0 - 7: Number of the affected component
(r0949):
Bit 8 - 31: Reserved
Remedy:
- Check cabinet design and cabling for EMC conformity.
- Replace affected component.
Acknowl.:
Immediate
F35872
CU DRIVE-CLiQ: fault in cyclic data transfer
F35873
Reaction:
OFF2
Cause:
Reserved for later use.
Remedy:
Reserved for later use.
Acknowl.:
Immediate
10-50