Multi Sensor Level Adjustment - Epson Stylus Pro 4000 Field Repair Manual

Hide thumbs Also See for Stylus Pro 4000:
Table of Contents

Advertisement

Stylus Pro 4000 Field Repair Guide
Note: This adjustment sets the "White Level" for the Multi Sensor (sensitivity calibration).
1. Load 17" Enhanced Matte roll paper.
2. From the
Adjustment Wizard

Multi Sensor Level Adjustment

Multi Sensor Level Adjustment
for the Pro 4000, select the
Printer Component,
Software Item,
Multi Sensor Level Adjustment
1. Click on the
2. The Printer will sample the paper with the
Multi Sensor to set a reference level.
3. The Printer will print out the data that was
written to the board. It will look like this.
4. Click the
Finish
LCD Display,
Printer Button
Run
button.
button.