Platen Position Adjustment - Epson Stylus Pro 4000 Field Repair Manual

Hide thumbs Also See for Stylus Pro 4000:
Table of Contents

Advertisement

Stylus Pro 4000 Field Repair Guide
1. Load 17" Enhanced Matte roll paper.
2. From the
Adjustment Wizard
OK = Good
NG = No Good

Platen Position Adjustment

Platen Position Adjustment
for the Pro 4000, select the
Printer Component,
Software Item,
Platen Position Adjustment.
1. Click on the
2. The Printer will print the alignment pattern
3. Measure the distance between the printed
line, and the tab at the edge of the border-
less printing pad as shown.
Note: If the alignment mark is 1mm to the
right of the tab at the edge of the bor-
derless pad, the correct offset value
would be 1.
Note: If the alignment mark is 1mm to the
left of the tab at the edge of the bor-
derless pad, the correct offset value
would be -1.
4. Enter the offset value.
5. Click on the
6. Click the
Next
LCD Display,
Printer Button
4/28/05
Print
button.
Write
button.
button.
Page 167.