Epson Stylus Pro 4000 Field Repair Manual page 8

Hide thumbs Also See for Stylus Pro 4000:
Table of Contents

Advertisement

Stylus Pro 4000 Field Repair Guide
Elec.: Record: Maintenance:
Lever, Cover, Ink Lever, Cr Motor, PF Motor, PrintNumber, Cleaning, Fire A, Fire B, Fire C, Fire
D, Fire E, Fire F, Fire G, Fire H, Cut, Cute Sole, LockSolen
Record: Error: Error (0 - 6)
D/A Revision: Measure Va: (nn.nnn)v
CSIC: Slot (1 - 8), Maintenance Tank
Actuator: Cutter: [Enter], Start
Actuator2: Cutter Sol, Pump Motor
Adjustment:
Cut Adj.: Pressure: *73%
PG ADJ: [Enter], Start: PG Offset *(nn)
Rear AD: [Enter], Start: Exc.: RearAD: (nnn nnn nnn)
Edge Sns Lvl: [Enter], Start:
Check Nozzle: [Enter] Print:
Check Skew: Check Skew: (n.n)mm (Default 1.0)
Clean Head:
Counter Clear: Reset Counter?
Ink Drain:
(Used for draining the ink system)
Cleaning:
Std. KK0
(Weakest cleaning cycle (uses less ink))
Std. KK1
(Medium strength cleaning cycle)
Std. KK2
(Strongest cleaning cycle)
Init. Fill
(Forces a initial fill (prime))
Print:
Check Ptn.: [Enter] Print
Adj. Variable: [Enter] Print
Parameter:
Initialize:
All: Initialize OK?
(Usage Counters for the following devices)
(Displays the last 7 errors)
(Tests the cutter assembly)
(Tests the following devices)
(Adjusts voltage used for the cutter solenoid)
(For adjusting the sensitivity of the edge sensor)
(Service level nozzle check)
(Used for draining the ink system)
(Resets all counters, DO NOT USE)
(Prints all alignment patterns)
(Prints the numeric adjustment variables currently set)
(Resets all of the following counters at once)
Printer Component,
(?)
(?)
(Used for adjusting the platen gap)
(For adjusting the rear paper sensor)
(Used for setting the amount of allowable skew)
Software Item,
LCD Display,
Printer Button
WasteInk, Wiper, Rubbing,
4/28/05
Page 8.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents