Back of thermostat
3. Remove the two screws holding the thermostat
to the control mounting panel.
Two screws
4. Remove the large rear panel by removing three
screws and lifting the panel out of the tabs.
Remove three screws
5. Remove the small cover from the rear of range by
removing one screw and pulling down.
One screw
5. Unclip the thermostat bulb inside the oven and pull
the bulb out the rear of the range.
Thermostat bulb
Rear of range with panels removed

Removing the large element safety thermostat:

1. Disconnect power and roll the control mounting
panel forward.
2. Disconnect the wires from the safety thermostat and
remove the two screws holding the thermostat to
the control mounting panel.
104