9.61 Fuser Fan
(1) Disconnect the Connector (CN4) from the High-voltage power supply PCB ASSY.
High-voltage power supply PCB ASSY
CN4
(2) Pull out the Fuser fan from the Paper eject ASSY by slightly rotating it in the arrow
direction in the figure below.
Fuser fan
Label
<Right side>
Connector
<Right side>
Fuser fan
Fig. 3-254
Fig. 3-255
3-171
Paper eject ASSY
Confidential