Before you begin the installation, read these entire instructions. You must locate an appropriate site (firm
and leveled surface) for the installation. Reading this section assists you with the decision making process.
Machine performance and the copy quality is subject to and dependant on environmental conditions.
To maintain good performance, quality, and safe operation, observe the following precautions:
1. For safe operation and to avoid trouble, do not install the system under the following conditions:
• Extremely high or low temperature and humidity.
Ambient conditions
• Sudden changes in temperature or humidity
• Exposed to direct sunlight
• Dusty environment
• Poorly ventilated location
• Exposed to chemical gases (such as ammonia gas)
• Exposed to strong vibration
• Exposed to direct air current (ex. Air conditioner vent)
2. The weight of the machine (options not included) is as follows:
UF-9000, DP-180/190: Approx. 48.5 lb (22 kg)
3. The maximum power consumption is 900 W for 120 VAC, or 1.0 kW for 220-240 VAC. Depending on
the product destination, the wall outlet must be rated for 120 VAC or 220-240 VAC accordingly. It must
also be protected for at least 15 Amps for 120 VAC, or 10 Amps for 220-240 VAC. If you are in doubt
about a power source, ensure that a qualified electrician checks the outlet. Do not connect any other
devices to the wall outlet designated for this machine. (Do not use an extension cord)
4. Make sure the outlet is properly grounded. (Do not ground to gas or water pipe)
5. The machine should be installed in a well-ventilated area to minimize the ozone density in the air.
6. This machine has ventilation openings on the side and rear, which must remain unobstructed for safe
operation. The machine should be located at least 3.94 inches (100 mm) from the wall. Obstructing the
ventilation openings could present a fire hazard.
Using the space requirements shown the following page, ensures that the machine has the ventilation
it requires and that you have the space needed for replacing the supplies.
Ver. 3.0
Temperature: 50 - 86 °F (10 - 30 °C)
Relative humidity: 30 - 80 %