CONNECTING THE DOUBLE OVEN MAINS CABLE
– Unscrew the screws A securing the cover plate B behind the oven (fig. 7.1).
– Remove the cover plate B.
– Remove the screws C from the cable clamp (fig. 7.2).
– Insert the mains cable (type H05RR-F or H05VV-F - 3x2,5 mm
protector P.
– Connect the phase and earth cables to the mains terminal connection block D.
N
L
Attention ! Make sure the wires have been well inserted into the contacts and
have been screwed down well.
– Refit the cable clamp so that it clamps the outer sleeving of the cable, and screw the
screws C.
– Refit the cover plate B and fix it with the screws A.
EARTH
NEUTRAL
LIVE
A
B
Fig. 7.1
WARNING: This appliance must be earthed
2
section) into the cable
Brown (Live)
Blue (Neutral)
P
C
D
Green
&
Yellow
(Earth)
Fig. 7.2