Use Program 20-46 : Security Sensor Setup to defines the security sensor.
Input Data
Security Sensor Number
Item
Item
No.
01
Sensor Mode
02
Internal Paging Group
for Warning Message
03
Ring Timer
04
VRS Message for
Warning
05
Auto Dial Number
Area Setting
06
VRS Message for An-
swer
07
Auto Dial Wait Timer
08
Time of Repeat Auto
Dial
09
Auto Dial Calling
Time
10
Monitored Terminal
11
Interval of Auto Dial
Conditions
None
Feature Cross Reference
None
Programming Manual
Program 20 : System Option Setup

20-46 : Security Sensor Setup

Input Data
0 = Off
Define door port (084M 3, 4) to use as
1 = On
Sensor.
0 ~ 32
Define Internal paging group number for
Warning message
0 ~ 8
Define External paging group number for
Warning message.
0 ~ 100
Define VRS number used for Warning
message.
0 ~ 999
Define Speed dial number when sensor
detects warning.
0 ~ 100
Define VRS message number when emer-
gency call destination answered.
0 ~ 64800
Define wait time before making emergency
auto dial.
0 ~ 255
Define repeat number for making emer-
gency call.
0, 1 ~ 3600
Define calling continue time when making
0 = No Auto Dial
emergency call.
Extension Number (Up
Define extension number for monitor from
to 8 digits)
outside. IP terminal cannot set as moni-
tored extension.
0 ~ 3600
1 ~ 6
Description
SL1100
Program
20
Default
0
0
0
0
0
0
30
3
30
No Setting
0
2-221