Security Sensor Setup - NEC SL1100 Programming Manual

Hide thumbs Also See for SL1100:
Table of Contents

Advertisement

SL1100
Level:
IN
Description
Use Program 20-46 : Security Sensor Setup to defines the security sensor.
Program
20
Input Data
Item
No.
01
Sensor Mode
02
Internal Paging Group
for Warning Message
03
Ring Timer
04
VRS Message for
Warning
05
Auto Dial Number
Area Setting
06
VRS Message for An-
swer
07
Auto Dial Wait Timer
08
Time of Repeat Auto
Dial
09
Auto Dial Calling
Time
10
Monitored Terminal
11
Interval of Auto Dial
Conditions
None
Feature Cross Reference
None
2-222
Program 20 : System Option Setup
Security Sensor Number
Item
Input Data
0 = Off
1 = On
0 ~ 32
0 ~ 8
0 ~ 100
0 ~ 999
0 ~ 100
0 ~ 64800
0 ~ 255
0, 1 ~ 3600
0 = No Auto Dial
Extension Number (Up
to 8 digits)
0 ~ 3600

20-46 : Security Sensor Setup

1 ~ 6
Description
Define door port (084M 3, 4) to use as
Sensor.
Define Internal paging group number for
Warning message
Define External paging group number for
Warning message.
Define VRS number used for Warning
message.
Define Speed dial number when sensor
detects warning.
Define VRS message number when emer-
gency call destination answered.
Define wait time before making emergency
auto dial.
Define repeat number for making emer-
gency call.
Define calling continue time when making
emergency call.
Define extension number for monitor from
outside. IP terminal cannot set as moni-
tored extension.
Program 20 : System Option Setup
ISSUE 6.0
Default
0
0
0
0
0
0
30
3
30
No Setting
0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents