ISSUE 6.0
Item
Item
No.
05
Message Backup/Go
Ahead Time
07
Digital Pager Callback
Number
08
Delay in Dialing Digi-
tal Pager Callback
Number
09
Wait Between Digital
Pager Callout At-
tempts
Programming Manual
Input Data
1 ~ 6015 seconds
(Msg Bkup/Adv Time)
Use this option to set the backup/ go
ahead time. This time sets how far InMail
backs up when a user dials B while listen-
ing to a message. This interval also sets
how far InMail jumps ahead when a user
dials G while listening to a message.
Digits
(Pager CBack)
(12 maximum, using 0 ~
Use this option to set the Digital Pager
9, # and
)
Callback Number portion of the Message
*
M (Number of messages
Notification callout number for a digital
- entered by pressing
pager. This is the portion of the callout
LK1)
number that is appended to the pager
X (Extension number -
service telephone number. Normally, this
entered by pressing
option should be X
LK2)
• X is the number of the extension that
InMail automatically re-
generated the notification.
places the X command
*
is a visual delimiter (to make the pag-
with the number of the
er display easier to read).
extension that initially re-
• M is the number of new messages in the
ceived the message.
extension mailbox.
• # is the digit normally used by the pager
service for positive disconnect.
0 ~ 99 seconds
(Pager Dial Delay)
Use this option to set the delay (0 ~ 99
seconds) that occurs just before InMail di-
als the Digital Pager Callback Number por-
tion of the Message Notification callout
number for a digital pager.
Set this delay so the pager service has
enough time to connect to the digital pager
before sending the callback number.
Your pager service may be able to help
you determine the best value for this op-
tion (0 ~ 99 seconds).
By default, this option is 9 seconds. When
placing a digital pager notification, the sys-
tem: Seizes the trunk specified. Dials the
user-entered notification number (in Mes-
sage + OP + N).
Waits the 47-01-08: Delay in Dialing Digi-
tal Pager Callback Number interval.
Dials the number entered in 47-01-07:
Digital Pager Callback Number.
The system assumes that the notification
number completes dialing approximately 4
seconds after trunk seizure. This means
that, by default, the Digital Pager Callback
Number is dialed into the pager service
about 13 seconds after trunk seizure.
1 ~ 255 minutes
(Notify Pager Intvl)
Use this option to set the minimum time (1
~ 255 minutes) between unacknowledged
or unanswered digital pager Message No-
tification callouts. (A subscriber acknowl-
edges a digital pager notification by log-
ging onto their mailbox.)
After this time expires, InMail tries the cal-
lout again (for up to the number of times
set in 47-01-14: Number of Callout At-
tempts).
If the system dials the callout number and
the pager service is busy, it retries the
number in one minute.
Description
*
M#, where:
SL1100
Default
5 seconds
X
M#
*
Program
47
30 seconds
15 minutes
2-409