NEC SL1100 Programming Manual page 152

Hide thumbs Also See for SL1100:
Table of Contents

Advertisement

SL1100
Item
No.
58
Display mode of
trunk incoming
(V1.5 Deleted)
60
Soft Key/Naviga-
tion key Mode
61
Backlight Max
Brightness
62
Backlight Min
Brightness
Program
63
Auto Backlight
64
Auto Backlight
15
bound threshold
(auto setting)
65
Auto Backlight
bound threshold
(manual setting)
66
Dial Button
Backlight
67
Caller ID shared
groups
68
Mode setting for
incoming call
from extension
69
Mute Operation
on Handsfree
(3.0 Added)
70
Mute Key Opera-
tion (V2.0 Added)
71
Disable Softkey
(V3.0 Added)
Lamp Cycle On/Off Timing Pattern (Program 15-02-35, 36, 38)
1
2
3
4
5
6
7
2-132
Item
Input Data
0 = Caller ID
1 = Memo Information
0 = Standard Mode
1 = Advanced Mode1
2 = Advanced Mode2
0 ~ 8
0 ~ 8
0 = Off
1 = On
0 ~ 13
0 ~ 13
0 = Off
1 = On
0 = Personal
1 ~ 8 = Shared Group
Read Only:
0 = Voice
1 = Signal
0 = Do not change
Mute status
1 = Start with enabled
Mute
2 = Start with muted
Mute
0 = Enabled (Active)
1 = Disabled
0 = Off
1 = On
Programs 15-02-35, 36, and 38
Input
Cycle 1
500 ms - ON / 500 ms - OFF
Cycle 2
250 ms - ON / 250 ms - OFF
Cycle 3
125 ms - ON / 125 ms - OFF
Cycle 4
125 ms - ON / 125 ms - OFF / 125 ms - ON / 625 ms - OFF
Cycle 5
875 ms - ON / 125 ms - OFF
Cycle 6
625 ms - ON / 125 ms - OFF / 125 ms - ON / 125 ms - OFF
Cycle 7
1000 ms - ON
Description
This program can only be
change by using PC Program-
ming.
This program determines whether
the Mute key is operational during a
call.
When set to 1 (On), disable Softkey
and cursor key operation at the ter-
minal.
Cycle
Program 15 : Extension, Basic Setup
ISSUE 6.0
Default
Related
Program
0
13-04-08
13-04-09
13-04-10
2
6
0
0
15-02-64
13
15-02-63
0
1
0
20-49-01
1
0
0
0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents