Department Group Assignment For Extensions - NEC SL1100 Programming Manual

Hide thumbs Also See for SL1100:
Table of Contents

Advertisement

ISSUE 6.0
Program 16 : Department Group Setup

16-02 : Department Group Assignment for Extensions

Level:
IN
Description
Use Program 16-02 : Department Group Assignment for Extensions to set the Department
Groups. The system uses these groups (32 Department Groups) for Department Calling. Assign pilot
numbers to Department Groups you set up in Program 11-07. This lets system users place calls to the
departments. Use Program 16-01 to set the priority of each extension in each Department Group.
When a call comes to the group, the extensions ring in order of their priority.
Input Data
Extension Number
Item
Item
Input Data
No.
01
Group Num-
1 ~ 32
ber
Priority
1 ~ 999
The initial value of a priority becomes the ports numerical order assigned in Programs 11-02 and 11-04.
(Extension ports are 1 ~ 128 (V3.5 or higher) Virtual extension ports are 1 ~ 50.)
Conditions
None
Feature Cross Reference
• Department Calling
Programming Manual
Default
Description
1 - xxx
Set up the Department Group called
by the pilot number and the exten-
(See
)
sion priority when a group is called.
Call Pickup Groups are set up in
23-02.
Maximum eight digits
Related Program
11-07
16-01
SL1100
Program
16
2-165