Switching Procedure
1. Enter the maintenance mode menu.
(1) Press the MAINTENANCE switch with a sharp tip. The maintenance information display will be
shown.
(2) While pressing the [SFT] (shift) key, press the [F8] (MAINTE EXEC) key to enter the mainte-
nance mode menu.
2. Press the [F9] (OTHERS CHECK) key to set the OTHERS CHECK screen.
3. Press the [F9] (SYSTEM MENU) key to set the SYSTEM MENU screen.
4. Press the [F2] (SYSTEM FREQ) key, select system frequency mode, and press the [F9] (EXEC)
key. The message to confirm the selection will be displayed. If OK, press the [F9] (EXEC) key
again. System initialization will be executed, and a new setting will be performed.
5. Turn OFF the power once, and then turn it ON again.
CH.COND
S Y S T E M M E N U
S Y S T E M
F R E Q
[ F 2 ] S Y S T E M F R E Q U E N C Y . ( 2 3 . 9 8 P s F )
M O D E 1
[ F 3 ] S D I O U T .
[ F 8 ] C a n c e l
D - C O N V
[ F 9 ] E x e c u t e o f R e s e t V T R S y s t e m .
S D I
w i t h c o n d i t i o n s
D 2
S T O P & n o t S T A N D B Y
E J E C T T a p e
(This screen is an example)
n
At shipment, 23.98 PsF will be selected.
HDW-F500E MMP1
RESETABLE
( D 1 / D 2 )
C A N C E L
E X E C
E X I T
1-8. Switchable Functions
1-33