1-8. Switchable Functions

1-8-2. Line Conversion Switchable Function of HKDV-502 (Option Board)

When the option board HKDV-502 (HD line converter board) has been installed, the number of effective
lines of HD SDI OUT are converted and output.
When the option board HKDV-502 (HD line converter board) has been installed, it is possible to convert
and output the effective lines of HD SDI OUT.
Switching Procedure
1. Enter the maintenance mode menu.
(1) Press the MAINTENANCE switch with a sharp tip. The maintenance information display will be
shown.
(2) While pressing the [SFT] (shift) key, press the [F8] (MAINTE EXEC) key to enter the mainte-
nance mode menu.
2. Press the [F9] (OTHERS CHECK) key to set the OTHERS CHECK screen.
3. Press the [F9] (SYSTEM MENU) key to set the SYSTEM MENU screen.
4. Press the [F1] (ACTIVE LINE) key to select "1035," "1080" or "off," then press the [F9] (EXEC)
key. Since the message for confirming the selection is appeared on the display, press the [F9]
(EXEC) key again if it is okay. System initialization will be executed, and a new setting will be
made.
5. Turn OFF the power once, and then turn it ON again.
CH.COND
A C T I V E
L I N E
1 0 3 5
S Y S T E M M E N U
S Y S T E M
F R Q
[ F 1 ] A C T I V E L I N E C O N V E R T E R
5 9 . 9 4
[ F 2 ] S Y S T E M F R E Q U E N C Y . ( 6 0 / 5 9 . 9 4 )
[ F 3 ] S D I O U T .
D - C O N V
[ F 8 ] C a n c e l
S D I
[ F 9 ] E x e c u t e o f R e s e t V T R S y s t e m .
D 1
w i t h c o n d i t i o n s
S T O P & n o t S T A N D B Y
E J E C T T a p e
(This screen is an example)
m
. It is set to "off" at shipment.
. The number of effective lines cannot be converted when it is set to off. When it is off, on/off control of
picture-quality improvement mode in SLOW mode (setup menu 732) can be performed.
. When the "1035" has been selected, it is correctly converted to the number of effective lines (1035
lines) in accordance with conversion mode of setup menu 730.
. When the "1080" has been selected, it is correctly converted to the number of effective lines (1080
lines) in accordance with conversion mode of setup menu 731.