Program 80 : Basic Hardware Setup for System
Level:
IN
Description
Use Program 80-01 : Service Tone Setup to define up to 64 Service Tones.
Each service tone is defined by the combination of 32 Basic Tones.
Input Data
Item
No.
01
Item
No.
02
03
04
Programming Manual
Service Tone Number
Item
Repeat Count
0~255 (0 = until On-Hook)
Unit Number
Item
1~33
Basic Tone Number
(0 = No Tone)
(33=Default Time Slot)
1~255 (100~25500ms)
Duration Count
Gain Level (dB)
1~63 (-15.5 ~ +15.5)
80-01 : Service Tone Setup
01~64
Input Data
1~8
Input Data
Program
80
2 - 583