Hardware Diagnostics
06. SCSI HDD TEST checks the HDD functions connected to the SCSI-Bus through
ASPI driver software. Before starting the test, select the following parameters.
HOST ID NUMBER
SCSI ID NUMBER
CHANNEL NUMBER
- 01. Sequential address read subtest is a sequential reading of all the blocks on the
HDD starting at block 0.
- 02. Connection subtest reads the logical sector at the end of the HDD and then
recognizes if the drive is connected or not.
NOTE: The 01. SEQUENTIAL ADDRESS READ tests all area of the hard disk
drive. Depending on the capacity of the installed hard disk drives, the test may take
a few hours.
If you do not know where the hard disk drives are connected (host ID, SCSI ID and
channel number of the SCSI controller), you can find them 01. INQUIRY of 09.
SCSI TEST.
SCSI HDD TEST (HDD) Error Log
Status
01
03
04
05
09
0D
0E
80
81
82
Parameter
Error name
CHECK CONDITION OR BAD
COMAND
DRIVE SELECTION FAILED
TARGET DRIVE BUSY
SCSI BUS TIME OUT
DMA BOUNDARY ERROR
COMMAND TERMINATED
QUEUE FULL
NO SENSE
RECOVERD ERROR
NOT READY
HW Diagnostics Program Main Menu
Sets the target host adapter number. When you
choose "ALL", the subtest tests all disks connected
to the server, and the next options, SCSI ID and
CHANNEL number will be ignored.
Sets the SCSI ID to test. You can specify just one ID
to test except ID:7.
If the server has multiple SCSI channels, this option
sets the channel number to test.
Bad command error
Drive selection error
Target drive is busy
Time out error of SCSI bus
DMA BOUNDARY occurred
Command terminated
Command queue is full
Sense data is invalid
Execution of the command has
correctly finished because of
recovery treatment.
Condition does not satisfy for the
command execution
Meaning
Meaning