The output shows that an incremental upgrade applies and the HTTP and CFA modules will be rebooted
during the upgrade process.
# Upgrade the HTTP feature on the standby MPU.
<Sysname> issu load file feature flash:/http-r0202.bin slot 1
This operation will delete the rollback point information for the previous upgrade and
maybe get unsaved configuration lost. Continue? [Y/N]:y
Upgrade summary according to following table:
flash:/http-r0202.bin
Running Version
Alpha 0201
Slot
1
1.1
Upgrading software images to compatible versions. Continue? [Y/N]: y
# Perform an active/standby switchover.
<Sysname> issu run switchover
Upgrade summary according to following table:
flash:/http-r0202.bin
Running Version
Alpha 0201
Slot
0
0.1
Upgrading software images to compatible versions. Continue? [Y/N]: y
# Display active software images.
<Sysname> display install active
Active packages on slot 0:
flash:/boot-r0201.bin
flash:/system-r0201.bin
flash:/http-r0201.bin
Active packages on slot 0.1:
flash:/boot-r0201.bin
flash:/system-r0201.bin
flash:/http-r0201.bin
Active packages on slot 1:
flash:/boot-r0201.bin
flash:/system-r0201.bin
flash:/http-r0202.bin
Active packages on slot 1.1:
flash:/boot-r0201.bin
flash:/system-r0201.bin
flash:/http-r0202.bin
CFA
New Version
Alpha 0202
Upgrade Way
Service Upgrade
File Upgrade
New Version
Alpha 0202
Switchover Way
Active standby process switchover
Active standby process switchover