HP 12500 Configuration Manual page 196

Routing switch series
Table of Contents

Advertisement

Notification
Level-2 alarm notification
Level-3 alarm notification
Level-3 alarm cancellation
notification
Level-2 alarm cancellation
notification
Level-1 alarm cancellation
notification
Figure 56 Memory alarm notification and alarm cancellation notification
Free memory space
Normal
Level-1
alarm
Level-1 (minor)
Level-2 (severe)
Level-3 (critical)
To set memory usage thresholds:
Step
1.
Enter system
view.
Triggering condition
The amount of the free memory space
goes down to or below the Level-2
alarm threshold for the first time.
The amount of the free memory space
goes down to or below the Level-3
alarm threshold for the first time.
The amount of the free memory space
goes up to or above the Level-2 alarm
threshold.
The amount of the free memory space
goes up to or above the Level-1 alarm
threshold.
The amount of the free memory space
goes up to or above the normal level
threshold.
Level-2
alarm
Level-3
alarm
Command
system-view
188
Remarks
After generating and sending a Level-2
alarm notification, the system does not
generate and send any additional
Level-2 alarm notifications until the first
Level-2 alarm is canceled.
After generating and sending a Level-3
alarm notification, the system does not
generate and send any additional
Level-3 alarm notifications until the first
Level-3 alarm is canceled.
N/A
N/A
N/A
Level-1 alarm
cancellation
notification
Level-2 alarm
cancellation
notification
Level-3 alarm
cancellation
notification
Remarks
N/A
Time