Siemens SINUMERIK 840D sl Programming Manual page 249

Measuring cycles hmi sl
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Measurement path (Measurement path factor)
Parameter: _FA
_FA should be selected to be greater than the mechanical clearance (A) when pre-
positioning the probe.
Range (Safe area)
Parameter: _TSA
Probe number (Number of probe field)
Parameter: _PRNUM
Measuring feedrate (Measuring feedrate)
Input field for the measuring feedrate
Parameter: _VMS
Protocol file (Measurement data protocol file)
Selection:
● No (default)
● yes
The protocol file is saved in the current NC data path (or workpiece) in which the
measurement program is running. The file name is the same as that of the swivel data
record plus "_M1". If the file name already exists, M1 is incremented (up to M99).
If the protocol file is activated, the intermediate results, i.e., the three center points of the
calibration ball (corresponding to 1st, 2nd and 3rd measurements) are logged.
The user is responsible for all protocol file operations (deleting, unloading, saving, etc.)
Measuring cycles
Programming Manual, 03/2009 Edition, 6FC5398-4BP10-2BA0
Measuring Cycles for Milling and Machining Centers
5.10 CYCLE996 workpiece: Measure kinematics
249