Traverse Selection; Traverse Acceleration Time/Traverse Deceleration Time; Traverse Step; Traverse Jump Step - Toshiba H9 ASD Installation And Operation Manual

Adjustable low voltage heavy duty industrial speed drive
Hide thumbs Also See for H9 ASD:
Table of Contents

Advertisement

F980

Traverse Selection

Program Special Traverse
This parameter setting is used in the setup of the Traverse control mode of
operation and is used in conjunction with the discrete terminal activation of the
Traverse Permission Signal.
This parameter is used to enable the Traverse function. The Traverse function
is activated via the discrete input terminal (see
See the Traverse Control Instruction Manual (P/N 58693) for more
information on this feature.
Settings:
0 — Disabled
1 — Enabled
Traverse Acceleration Time
Program Special Traverse
This parameter setting is used in the setup of the Traverse control mode of
operation. This setting establishes the acceleration rate used during the
Traverse function.
See the Traverse Control Instruction Manual (P/N 58693) for more
information on this feature.
Traverse Deceleration Time
Program Special Traverse
This parameter setting is used in the setup of the Traverse control mode of
operation. This setting establishes the deceleration rate used during the
Traverse function.
See the Traverse Control Instruction Manual (P/N 58693) for more
information on this feature.

Traverse Step

Program Special Traverse
This parameter setting is used in the setup of the Traverse control mode of
operation. This setting is used as a multiplier to establish the amount that the
frequency is increased or decreased while using the Traverse function.
See the Traverse Control Instruction Manual (P/N 58693) for more
information on this feature.

Traverse Jump Step

Program Special Traverse
This parameter setting is used in the setup of the Traverse control mode of
operation. This setting is used as a multiplier to establish the amount that the
frequency is increased or decreased while using the Traverse function when a
short burst of rapid speed change is required.
See the Traverse Control Instruction Manual (P/N 58693) for more
information on this feature.
H9 ASD Installation and Operation Manual
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Table 5 on pg.
234).
Direct Access Number — F980
Parameter Type — Selection List
Factory Default — Disabled
Changeable During Run — No
Direct Access Number — F981
Parameter Type — Numerical
Factory Default — 25.0
Changeable During Run — No
Minimum — 0.1
Maximum — 120.0
Units — Seconds
Direct Access Number — F982
Parameter Type — Numerical
Factory Default — 25.0
Changeable During Run — No
Minimum — 0.1
Maximum — 120.0
Units — Seconds
Direct Access Number — F983
Parameter Type — Numerical
Factory Default — 10.0
Changeable During Run — No
Minimum — 0.0
Maximum — 25.0
Units — %
Direct Access Number — F984
Parameter Type — Numerical
Factory Default — 10.0
Changeable During Run — No
Minimum — 0.0
Maximum — 50.0
Units — %
F984
233

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

P9 asd

Table of Contents