Array Rear View - NEC D3-10i Quick Start Manual

San storage
Table of Contents

Advertisement

Array Rear View

The rear of the base unit provides access to the base unit's two power supply modules (PS 0 and PS 1) and
two controller modules (Controller 0 and Controller 1), as seen in Figure 4 below.
PS 1
Power Supply Cable Clamp
Controller 1
SAS Ports and LEDs
Power Supply Status LEDs
There are three status LEDs on each power supply that include, from left to right, a power-on LED, a power
fault LED, and a fan fault LED, which indicate the status for each power supply module as follows.
LED
Indication
Power On LED
Solid Green
Solid Orange
Power Fault
LED
Blinking Orange
Fan Fault LED
Solid Orange
Controller SAS Port
The SAS ports are used to connect the base unit to additional disk enclosures and have two Status LEDs, a
green Link LED on the left and an Orange Fault LED on the right.
iSCSI Host Ports
The ports labeled iHP on the base unit controllers are iSCSI Host Ports that are used to connect the array
to the application servers. There are two iSCSI Ports on each controller and each array unit can have either
one or two controllers for a maximum of four iSCSI ports per array.
Management and Maintenance Ports
The management port provides the network connection for the management server. The maintenance port
is only for use by NEC-authorized service professionals.
NEC D3-10i Quick Start Guide
iSCSI Host Ports
Power Button
Figure 4. Base Unit Rear View
When lit, indicates that the power supply is on
Indicates that a fault condition exists in the power supply itself
Indicates that there is an abnormal thermal condition in the power supply
or that the other power supply bay is empty
When lit, indicates that a fault condition exists in the power supply's fan
Table 4. Power Supply LED Status Conditions
Power Supply Status LEDs
Controller Status LEDs
Management LAN Port
Description
PS 0
Controller 0
Maintenance Port
5

Advertisement

Table of Contents
loading

Table of Contents