X1
1
L1
2
N
3
PE
PE
Housing
F1
T6.3 A
S2
Figure 9-6
HiPath 3500, HiPath 3300 - ECR With Batteries and EPSU2-R
Caution
7
When storing an ECR equipped with batteries or if the ECR is inactive for a long pe-
riod of time, remove the battery fuse (6.3 A/T) in the front panel of the ECR.
When shipping an ECR with built-in batteries, the batteries must be removed before-
hand.
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
S1
–48 V BatE
Batt
+48 V
–48 V BatB
+48 V
Expanding and Upgrading HiPath 3000
Input
EPSU2-R
–48 V CD
Out
+48 V
4 batteries
12 V/7 Ah
Expanding HiPath 3000
L1
N
PE 3
+48 V
–48 V UP
Fan
(not available with all
systems)
exup.fm
X2
1
2
X3
3
4
1
2
9-19